4 resultados para Antibodies, Blocking

em eResearch Archive - Queensland Department of Agriculture; Fisheries and Forestry


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The ability of blocking ELISAs and haemagglutination-inhibition (HI) tests to detect antibodies in sera from chickens challenged with either Avibacterium (Haemophilus) paragallinarum isolate Hp8 (serovar A) or H668 (serovar C) was compared. Serum samples were examined weekly over the 9 weeks following infection. The results showed that the positive rate of serovar A specific antibody in the B-ELISA remained at 100% from the second week to the ninth week. In chickens given the serovar C challenge, the highest positive rate of serovar C specific antibody in the B-ELISA appeared at the seventh week (60% positive) and was then followed by a rapid decrease. The B-ELISA gave significantly more positives at weeks 2, 3, 7, 8 and 9 post-infection for serovar A and at week 7 post-infection for serovar C. In qualitative terms, for both serovar A and serovar C infections, the HI tests gave a lower percentage of positive sera at all time points except at 9 weeks post-infection with serovar C. The highest positive rate for serovar A HI antibodies was 70% of sera at the fourth and fifth weeks post-infection. The highest rate of serovar C HI antibodies was 20% at the fifth and sixth weeks post-infection. The results have provided further evidence of the suitability of the serovar A and C B-ELISAs for the diagnosis of infectious coryza.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A panel of 19 monoclonal antibodies (mAbs) was used to study the immunological variability of Lettuce mosaic virus (LMV), a member of the genus Potyvirus, and to perform a first epitope characterization of this virus. Based on their specificity of recognition against a panel of 15 LMV isolates, the mAbs could be clustered in seven reactivity groups. Surface plasmon resonance analysis indicated the presence, on the LMV particles, of at least five independent recognition/binding regions, correlating with the seven mAbs reactivity groups. The results demonstrate that LMV shows significant serological variability and shed light on the LMV epitope structure. The various mAbs should prove a new and efficient tool for LMV diagnostic and field epidemiology studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop and validate an ELISA for detecting chicken antibodies to Eimeria tenella. An initial comparison of merozoite and sporozoite antigen preparations revealed few differences in their ability to monitor the onset, kinetics and magnitude of the antibody response suggesting that both antigens would be equally useful for development of an ELISA. Furthermore the cross-reactivity of these antigens with sera from birds infected with chicken Eimeria species was similar. The merozoite antigen was selected for further evaluation because it was easier to prepare. Discrimination between sera from birds experimentally infected with E. tenella and birds maintained in an Eimeria-free isolation facility was excellent. In sera collected from free-range layers and commercial broilers there also appeared to be clear discrimination between infected and uninfected birds. The ELISA should prove useful for monitoring infectivity in vaccination programmes in layer and breeder flocks and for assessing the effectiveness of biosecurity measures in broiler flocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A competitive enzyme-linked immunosorbent assay (cELISA) based on a broadly conserved, species-specific, B-cell epitope within the C terminus of Babesia bigemina rhoptry-associated protein 1a was validated for international use. Receiver operating characteristic analysis revealed 16% inhibition as the threshold for a negative result, with an associated specificity of 98.3% and sensitivity of 94.7%. Increasing the threshold to 21% increased the specificity to 100% but modestly decreased the sensitivity to 87.2%. By using 21% inhibition, the positive predictive values ranged from 90.7% (10% prevalence) to 100% (95% prevalence) and the negative predictive values ranged from 97.0% (10% prevalence) to 48.2% (95% prevalence). The assay was able to detect serum antibody as early as 7 days after intravenous inoculation. The cELISA was distributed to five different laboratories along with a reference set of 100 defined bovine serum samples, including known positive, known negative, and field samples. The pairwise concordance among the five laboratories ranged from 100% to 97%, and all kappa values were above 0.8, indicating a high degree of reliability. Overall, the cELISA appears to have the attributes necessary for international application.